Dixell Cx 660 Manual
• Installation and Operating Instructions Regulation restart with door open alarm: 0= n = no; 1= Y = yes, regulation will restart after “door open” alarms. Probe selection for Condenser Alarm: 0= nP=No Probe selected 1= P1=Probe 1 2= P2=Probe 2 3= P3=Probe3 *normally P3 would be used* Low temperature alarm of condenser: (-55 to 150°C or -67 to 302°F) when this temperature is reached, the HA2 alarm will be raised (after the Ad2 delay time has expired).
Dixell Cx 660 Manual Portugues
Innovation and efficiency for a better environment Dixell technology is leading the way in electronic regulation and control in the fields of refrigeration, air conditioning and heating, and retail. Dedication to technological innovation and constant focus on efficiency have driven the development of solutions designed to maximize energy savings. Dixell parametric controllers, fan speed controllers and inverters, compressor controls, EEV drivers, sensors and monitoring systems are trusted around the world. These industrial and commercial products play an important role in ensuring human comfort and protecting food throughout the cold chain.
View and Download Dixell XR06CX operating manual online. DIGITAL CONTROLLER WITH DEFROST AND FANS MANAGEMENT. XR06CX Network Router pdf manual download. View and Download Dixell UNIVERSAL XR60CX installation and operating instructions manual online. UNIVERSAL XR60CX Controller pdf manual download.
Housing self-extinguishing ABS Case CH keyboard: frontal 38x80mm; depth 23mmT keyboard: frontal 38x185mm; depth 23mmD, K: frontal 110x140mm; depth 48mm Mounting CH keyboard: panel mounting in a 29x71mm cut-outT keyboard: panel mounting in a 31x150mm cut-outD, K: DIN Rail or wall mounting through integrated brackets Front protection Keyboard CH, T: IP65 Connections screw terminal block. • Efficient case control thanks to device synchronization (up to 8) by local LAN • Optimized management of stepper or pulse electronic expansion valves • Low environmental impact (CO2, R407C and R407F compatible) • Energy saving through case optimization with auto-adaptive control of superheat • Energy consumption reduction thanks to ECI fan management via PWM or 0÷10V output • Anti-sweat heater management through a ”DEW POINT” • Virtual probe management • Keyboard with direct access to the main functions • Internal Real Time Clock • Hot Key for quick and easy programming.
It is provided with three relay outputs to control compressor, defrost - which can be both electrical or hot gas - and evaporator fans. • Installation and Operating Instructions Table 1: parameter “tC” settings Parameter Required Type of Control Models Replaced probes On / Off thermostat – Heating XR110C, XR01CX, XR10C, XR10CX Off cycle defrost (timed) XR120C, XR02CX, XR20C, XR20CX Off Cycle defrost time initiated / temperature terminated XR120C, XR02CX, XR20C-E Off Cycle defrost time initiated / temperature terminated, Alarm XR130C, XR03CX, XR30CX. • Installation and Operating Instructions 4. PARAMETER TABLE and factory default settings IMPORTANT: Always set parameter “tC” first. As you move “tC” between settings 1 to 7, all non-relevant parameters will be masked. After setting “tC”, it will be possible to modify all the other relevant parameters.
• ÷ the “did” interval, before signalling the alarm event (I2F= PAL). Instrument XR30CX shall be mounted on vertical panel, in a If the nPS activation in the did time is reached, switch off and on the instrument to 29x71 mm hole, and fixed using the special bracket supplied.
Cocina Ariston Cx 660 Manejo
Third probe calibration: (-12.0 to 12.0°C or -21 to 21°F) adjustment for third probe offset. • Installation and Operating Instructions Regulation restart with door open alarm: 0= n = no; 1= Y = yes, regulation will restart after “door open” alarms. Probe selection for Condenser Alarm: 0= nP=No Probe selected 1= P1=Probe 1 2= P2=Probe 2 3= P3=Probe3 *normally P3 would be used* Low temperature alarm of condenser: (-55 to 150°C or -67 to 302°F) when this temperature is reached, the HA2 alarm will be raised (after the Ad2 delay time has expired).
Probe Selection for first defrost cycle (Maximum) duration of defrost: (0 to 255min) time duration of a defrost cycle when only one probe is in use, or defrost time out override when second (evaporator) probe is in use. • Installation and Operating Instructions Third probe presence (probe named Evap.2 on the label): 0= n = not present, the third input (the one signed with label “D.I. / Pb3”) Input operates as digital input; 1= Y = present, the third input (the one signed with label “D.I. / Pb3”) Input operates as third probe. Third probe calibration: (-12.0 to 12.0°C or -21 to 21°F) adjustment for third probe offset.
Amtlib 0.9.2 download. BUTTONS AND THEIR FUNCTIONS 6.1 SINGLE BUTTON FUNCTIONS Table 5: single button functions BUTTON FUNCTION Type Controller menu: keep this button pressed for at least 3 sec within 1 min after power on to enter the “Type Controller Menu” (tC). AUX output control: Switches the AUX relay output (if enabled as such). • Installation and Operating Instructions NOTE: the “Err” message is displayed for failed programming. In this case push o key again if you want to restart the upload or remove the “Hot key” to abort the operation. 8.2 HOW TO PROGRAM AN INSTRUMENT USING A HOT KEY (DOWNLOAD) Turn OFF the instrument.
Dixell Controller Xr60cx
• HOW TO SEE THE SET POINT • In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.p.A.” (see address) with a detailed description of the fault. Push and immediately release the SET key, the set point will be showed. • Resolution (only for °C):(dE ÷ in) dE= decimal between -9.9 and 9.9°C; in= integer Instrument XR06CX shall be mounted on vertical panel, in a Ld Default display: (P1 ÷ P2) P1= thermostat probe; P2= evaporator probe. SP=Set point (only 29x71 mm hole, and fixed using the special bracket supplied. • Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp.
• Installation and Operating Instructions UNIVERSAL–XR60CX 1. GENERAL DESCRIPTION Model Universal-XR is a 71x29 mm format microprocessor based controller, suitable for applications on high, medium or low temperature refrigeration units. It is provided with three relay outputs to control compressor, defrost - which can be both electrical or hot gas - and evaporator fans. • Installation and Operating Instructions Table 1: parameter “tC” settings Parameter Required Type of Control Models Replaced probes On / Off thermostat – Heating XR110C, XR01CX, XR10C, XR10CX Off cycle defrost (timed) XR120C, XR02CX, XR20C, XR20CX Off Cycle defrost time initiated / temperature terminated XR120C, XR02CX, XR20C-E Off Cycle defrost time initiated / temperature terminated, Alarm XR130C, XR03CX, XR30CX.
• 15.2 ALARM “EE” The Dixell Universal-XR is provided with an internal watchdog verifying data and memory integrity. Alarm “EE” will flash after detecting a failure in data or in the internal memory.
• Installation and Operating Instructions UNIVERSAL–XR60CX 1. GENERAL DESCRIPTION Model Universal-XR is a 71x29 mm format microprocessor based controller, suitable for applications on high, medium or low temperature refrigeration units.
• HOW TO SEE THE SET POINT • In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.p.A.” (see address) with a detailed description of the fault. Push and immediately release the SET key, the set point will be showed. • Resolution (only for °C):(dE ÷ in) dE= decimal between -9.9 and 9.9°C; in= integer Instrument XR06CX shall be mounted on vertical panel, in a Ld Default display: (P1 ÷ P2) P1= thermostat probe; P2= evaporator probe.